Model No.: SYS120VDC12000W
APM 6U high DC Source System meet your request of 10 kw Programmable Power Supply! Gives give you flexibility to mix and match to meet specific test requirements.Series connection of the 2U single dc rack mount Power Supply makes voltage up to 360V and max current of 120A in parallel connection.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● With accurate voltage and current measurement capability.
● Coded Knob, multifunction keyboard.
● Standard RS232/RS485/USB/LAN communication interfaces, GPIB is optional.
● Remote sensing line voltage drop compensation.
● Equips with LIST waveform editing function.
● Use the Standard Commands for Programmable Instrumentation(SCPI) communication protocol.
● Have obtained CE certification.
Technical Specification:
ltem | MODEL | SYS120VDC12000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 75A | |
5 | Input Power Max | 15kW | |
6 | Power Factor at 220VAC Input ,Full Load | 0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~120V | |
9 | Output Current | 0~120A | |
10 | Output Power | 12kW Max | |
11 | Load Regulation | Voltage | 120mV |
12 | Current | 0.12A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~120V |
16 | Resolution | 1mV | |
17 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
18 | Current Setting | Range | 0~120A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 160mVp-p/30mVrms |
22 | Current | 90mA(Full Range),15mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~120V |
24 | Resolution | 1mV | |
25 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc | |
26 | Current Setting | Range | 0~120A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~360V | |
30 | Output Current | 0~40A | |
31 | Output Power | 12kW Max | |
32 | Load Regulation | Voltage | 120mV |
33 | Current | 0.12A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~360V |
37 | Resolution | 10mV | |
38 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
39 | Current Setting | Range | 0~40A |
40 | Resolution | 0.1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 120mVp-p/22.5mVrms |
43 | Current | 120mA(Full Range),20mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~360V |
45 | Resolution | 10mV | |
46 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
47 | Current Setting | Range | 0~40A |
48 | Resolution | 0.1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232, LAN(Standard); GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*736.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*910.0*820.0 mm | |
67 | Unit Net Weight | 54kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 94kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
*F.S. represents the maximum value of the output range.
*N stands for the number of installed power supply units,and N is greater than 1.
Product Categories : DC Source System > 120V DC Source System